2
mr
.
steam
®
iGenie
™
Control
__________________________________________________________________
INSTALLATION & OPERATION MANUAL
IGENIE OPERATION
The iGenie is an optional way to turn the steambath on and off from
a
lmost anywhere in the house. The iGenie includes two parts - a
battery powered handheld FOB and a module that plugs into the
steam generator. The FOB communicates wirelessly with the module.
GENIE
™
MODULE INSTALLATION
• Connect the iGenie Module to the generator by plugging in
the provided 5 foot cable to the iGenie Module and the iGe-
nie connector on the side of the generator as shown.
• Mount the iGenie Module in a dry, indoor location. For maxi-
mum range, the iGenie Module should be mounted as high as
practical and away from metal that could effect the radio sig-
nal. Securing it to a nearby wood stud is ideal. The antenna
should be pointing upwards.
• With the generator powered, the red light (steam off) or green
light (steam on) should come on when plugged in.
Press the toggle steam button to confirm proper connection.
• Press the ON/OFF button and confirm that the iGenie lights
match the state of the steam generator. Red for Steam Off
(control is off) and green for Steam On (control is on).
• The yellow RF activity light on the iGenie Module should flash
each time the button on the iGenie FOB is pressed.
• Test the range of the iGenie FOB. It may be necessary to
change the location of the iGenie Module to improve the
range. Contact Mr.Steam technical service for an optional 60
foot cable, part number 103978-60.
iGENIE
™
FOB OPERATION:
• When the iGenie FOB light is off, press the iGenie FOB button
once and the iGenie FOB light indicates if the steam is on or off.
When you press the button, the light will momentarily twinkle
between red and green. A red light indicates that the steam is
off and a green light indicates that the steam is on. If you are
out of range, the lights will twinkle for about 5 seconds and then
shut off.
• To turn the steam on or off, press the ON/OFF button again
while the light is illuminated. After a short delay the light will
change from red to green (steam on) or green to red (steam off).
• The light will stay illuminated for 10 seconds and then shut off.
• A blinking red light indicates that an error condition exists in the
steam generator. An error code will be displayed on your
iTempo, iTempo/Plus or iSteam control. Contact the Mr.Steam
Technical Service Department at 800-76-STEAM (East coast)
or 800-72-STEAM (West coast) for assistance or additional in-
formation.
The iGenie FOB may be used in the steam room.
Do not submerge the iGenie FOB in water. Doing so may
result in an inoperative or hazardous installation.
Plug the iGenie Module cable
into the iGenie location on
the steam generator
NOTE: For illustrative purposes only.
The iTempo control cable is not shown for clarity. An iTempo, iTempo/Plus
or iSteam control must be used in conjunction with the iGenie.
iGenie
MODULE
i
Genie
MODUL
E Cable
ON/OFF Button
Red and Green
Indicating Light Ring
iGENIE FOB
On/Off
Button
Red/Green
Indicating
Light Ring
CAUTION
!